Xantrex-technology 175 PLUS Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Ferramentas Xantrex-technology 175 PLUS. Xantrex Technology 175 PLUS User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - 700 PLUS

Owner’s GuideXPower Inverter175 PLUS400 PLUS700 PLUSt 1-800-670-0707 (toll free)t 604-422-2777f 604-420-2145e [email protected]

Página 2 - 400 Plus, 700 Plus

92 Important Safety Information Misusing or incorrectly connecting the XPower may damage the equipment or create hazardous conditions for users. Read

Página 3 - Notice of Copyright

10Warning! Heated SurfaceThe XPower housing may become uncomfortably warm, reaching 140° F (60° C) under extended high power operation. Ensure that at

Página 4 - Contact Information

11 Caution!Some chargers for small nickel-cadmium batteries can be damaged if connected to the XPower. Do not use the inverter with the following appl

Página 5

12Additional Safety Guidelines• Do not insert foreign objects in the XPower outlets.• Never connect the inverter to power utility AC distribution wiri

Página 6 - Table of Contents

133 XPower FeaturesThis section describes the main features of the XPower inverters.AC (Front) PanelFigure 1 shows the AC panel of the XPower 175 Plus

Página 7

14Figure 2 shows the AC panel of the XPower 400 Plus and XPower 700 Plus inverters.Figure 2 AC Panel of XPower 400 Plus and XPower 700 PlusAC Outlets

Página 8 - 1 Introduction

15XPower 400 Plus Two AC receptacles are located on one end of the XPower 400 Plus. You can plug in any 120-volt appliances with a combined total powe

Página 9 - About This Guide

16Ventilation OpeningsTo prevent overheating, ensure that the ventilation openings on the front and back panels are kept clear.DC (Back) PanelFigure 3

Página 10 - Warnings and Cautions

17Figure 4 shows the DC panel of the XPower 400 Plus and XPower 700 Plus inverters.Figure 4 DC Panel of XPower 400 Plus and XPower 700 Plus Fan and V

Página 11 - Warning! Explosion Hazard

18Positive and Negative Cabling Terminals:For XPower 400 Plus and XPower 700 Plus, you connect the ring terminals on the power cables to these termin

Página 12 - Caution!

XPower Inverter 175 Plus, 400 Plus, 700 PlusOwner’s Manual

Página 13 - Additional Safety Guidelines

19Figure 6 Cable for Direct Connection to 12 Volt BatteryCaution!The XPower 175 Plus can not power loads over 150 watts, so it is not equipped with c

Página 14 - 3 XPower Features

20Types of ConnectionsProduct Lighter Plug ConnectionCable Clamps/Battery ConnectionXPower 175 PlusAvailable - A cable is permanently attached to the

Página 15 - AC Outlets

214 Connecting the XPower Plus InvertersChoosing a LocationFor the best performance, place the inverter on a flat surface in a location that is:Cautio

Página 16

22DryDo not allow water or other liquids to splash on the inverter.CoolAmbient temperatures should be between 32° F and 104° F (0° C and 40° C) - the

Página 17 - DC (Back) Panel

23Connecting the XPower 175 Plus and XPower 400 Plus for Loads Under 150 WattsFollow these steps to connect the XPower 175 Plus or XPower 400 Plus inv

Página 18

244. Place the inverter’s lighter plug in the vehicle’s cigarette lighter socket or a 12 volt outlet.5. Turn on the front panel On/Off switch.The gree

Página 19 - Figure 5 Lighter Plug Cable

25Follow these steps to make a direct battery connection:1. Place the inverter on a flat surface.2. Make sure the On/Off switch on the front panel is

Página 20

263. Take the cables equipped with battery clips on one end (Figure 6) and place the ring terminals over the two cabling terminals on the back of the

Página 21 - Figure 6

274. Fasten the positive (red) clip to the positive battery post, and then fasten the negative (black) clip to the negative battery post.5. Turn on th

Página 22 - Inverters

285 Operating the XPower InverterThis section explains how to operate the XPower 175 Plus, XPower 400 Plus and XPower 700 Plus most efficiently.Operat

Página 23

iiAbout XantrexXantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units

Página 24

29Overload ShutdownIf you connect an AC load that is rated too high (see Table 1 on page 30) or a load that draws excessive surge power, the XPower sh

Página 25 - Plus for Loads Over 150 Watts

30Table 1 Power and Surge RatingsThe inverter’s AC (“modified-sine wave”) output waveform, is designed to function similarly to the sine wave shape of

Página 26 - Warning!

31Operating Loads With High Surge RequirementsThe power, or wattage, rating of AC loads is the average amount of power they use. Some appliances consu

Página 27 - Caution! Reverse Polarity

326 Maintaining Battery ConditionThe battery operating time of the XPower depends on the charge level of the battery, battery capacity, and the amount

Página 28

33battery will shorten its life. Therefore, when you are using a vehicle battery as a power source, start the vehicle every hour or two to recharge th

Página 29 - FAULT light comes on

347 TroubleshootingThis section will help you identify the source of most problems that can occur with the XPower inverter.If you have a problem with

Página 30

35Common ProblemsBuzz in Audio SystemsSome inexpensive stereo systems have inadequate internal power supply filtering and buzz slightly when powered b

Página 31 - XPower inverter

36Television InterferenceThe XPower is shielded to minimize interference with TV signals. If TV signals are weak, you may see interference in the form

Página 32

37The AC load will not operate. No inverter lights are on. Inverter will run some small loads, but not larger ones.Possible Cause Suggested RemedyBatt

Página 33 - Operating

38Measured inverter output is too low.Alarm is sounding.Possible Cause Suggested RemedyA standard “average-reading” AC voltmeter has been used to meas

Página 34

iiiDisclaimerWITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS SPECIFICALLY AGREED TO BY IT IN WRITING, XANTREX a) MAKES NO WARRANTY AS TO THE

Página 35 - 7 Troubleshooting

39Battery run time is less than expected. The AC load will not operate. The FAULT light is on. Possible Cause Suggested RemedyThe AC product power co

Página 36 - Common Problems

40The AC product(s) connected are rated at less than the inverter’s continuous power rating; high starting surge has caused overload shutdown.The prod

Página 37 - Troubleshooting Reference

418 Specifications Specifications are subject to change without notice.Table 1 XPower Plus SpecificationsXPower 175 Plus XPower 400 Plus XPower 700 Pl

Página 38

42XPower 175 Plus XPower 400 Plus XPower 700 PlusEfficiency (maximum)90% 90% 90% Ambient operating temperature range32° F – 104° F 0° C – 40° C32° F –

Página 39 - Alarm is sounding

439 Limited Warranty What does this warranty cover and how long does it last?This Limited Warranty is provided by Xantrex Technology, Inc. (“Xantrex”)

Página 40 - Table 1 on

44Period or 90 days from the date of the return shipment to the customer, whichever is greater. All replaced products and all parts removed from repai

Página 41

45Direct returns may be performed according to the Xantrex Return Material Authorization Policy described in your product manual. For some products, X

Página 42 - 8 Specifications

461. the product if it has been misused, neglected, improperly installed, physically damaged or altered, either internally or externally, or damaged f

Página 43

47OTHERWISE IN CONNECTION WITH THE PRODUCT, HOWEVER ARISING (WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES OF MANUFACTURER’S LIABILITY, OPERATION

Página 44 - Limited Warranty

48ExclusionsIf this product is a consumer product, federal law does not allow an exclusion of implied warranties. To the extent you are entitled to im

Página 46

49Return Material Authorization Policy Before returning a product directly to Xantrex you must obtain a Return Material Authorization (RMA) number and

Página 47

502. Include the following:• The RMA number supplied by Xantrex Technology Inc. clearly marked on the outside of the box.• A return address where the

Página 48

51Out of Warranty Service If the warranty period for your XPower Plus Inverter has expired, if the inverter was damaged by misuse or incorrect install

Página 49 - WARNING: Limitations on Use

vTable of Contents1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7About the XPower Plus Inverters . . . . . . .

Página 50

vi5. Operating the XPower Inverter . . . . . . . . . . . . . . . . 28Operating Conditions and Guidelines . . . . . . . . . . . . 286. Maintaining

Página 51

71 Introduction Thank you for purchasing an XPower Plus Inverter. The XPower 175 Plus, XPower 400 Plus, and XPower 700 Plus are part of a family of ul

Página 52 - 10 Other Xantrex Products

8• Low battery alarm• Low voltage shutdown• High voltage shutdown• Overload shutdown• Over temperature shutdown• Short circuit protectionAbout This Gu

Modelos relacionados 700 PLUS