Operation
24 975-0125-02-01
On Start Up
When the MS2000 is powered up or comes out of a reset state, all of the front
panel lights illuminate and remain on for a minimum of five seconds. After five
seconds, the lights remain illuminated until the front panel has status information
for all the lights.
The MS2000 is disabled every time the unit is powered up. The inverter must then
be enabled. When a function is disabled, it is not allowed to occur and if it is
occurring, it is terminated. Regardless of other conditions, the function will not be
activated. For example, even if AC power is present, if the charger is disabled, the
unit will not charge.
When a function is enabled, it is allowed to occur but other conditions may have
to be met before the function is activated or turned on. For example, the charger
function on the MS2000 may be enabled, but it will not charge unless qualified
AC power is present.
Power On Reset
To perform a power on reset, hold the reset button on the front panel for about 5
seconds. All front panel lights will illuminate to indicate that the unit has reset.
6 Up arrow button
Scrolls up one line of text.
Increases a selected value.
7 Down arrow button
Scrolls down one line of text.
Decreases a selected value.
8 Exit button
Cancels selection of a menu item.
Returns you to the previous screen.
9 System button:
Toggles all Xanbus-enabled devices on the system between
Operate mode and Power Save mode. See System Modes
on page 26.
10 Screen displays menus, settings, and system information.
Table 2-1
System Control Panel Features and Buttons